Elpan/Wanpan Skirting Board Radiant Heating Systems for Rental Property

Elpan/Wanpan skirting board radiant heating system for rental property provides fewer more benefits for renters as well as property owners concerning efficiency – lower heating energy consumption.

Programmable thermostats may be set up according tenants’ living style, work schedule, etc. or simply – maintain constant temperature and never has to be adjusted.

When rental property is vacant, owner can keep temperature at the lowest level (Elpan electric heating system can keep the lowest temperature of 5 degrees of C). Skirting board heating system has very low inertia, which allows it to be turned on only 30-45 min before inhabitants’ arrival. The manufacturer can supply a control, which can be fitted into the system of the rental or holiday home and started by SMS. The house will be lovely and warm, when residents will arrive.

Elpan/Wanpan skirting board radiant heating system installed in rental property gives property owners more flexibility to control heating energy consumption and use heating system more efficiently, which keeps property expenses at lower level.

For more information go to: www.wanpan-usa.com.

 
Leave a comment

Posted by on February 10, 2014 in Application, Efficiency

 

Tags: , , , , , , , , , , , , , , , , , , , , ,

No Limitations for Flooring with Elpan/Wanpan Radiant Heating System

There are no limitations or any kind of requirements or recommendations for using specific type of flooring when Elpan/Wanpan  skirting board radiant heating system is going toClick to enlarge be installed.  Skirting board heating system does not heat floor from bellow and flooring is not affected by higher temperatures.

Infloor radiant heating system may not be recommended to be installed if you are planning to have wood floor, because of wood heat resistance, which is very high. When radiant infloor heating system is chosen as the  type of  heating with wood floor, energy consumption of the house is expected to be much higher. In addition to high energy consumption, more rapid change of heating temperature is affecting wood floor shape as well as quality of the flooring.

Marble tiles or synthetic flooring could be the only choices at this point.  Many companies are providing customers with informative and useful instructions for synthetic flooring. Besides, consumers need to be aware of the fact, that higher temperatures may cause unhealthy release of chemicals from synthetic flooring at least for the first few days of heating premises.

Elpan/Wanpan heating system can be installed with no additional precautions or limitations for the different types of flooring. There are no any kind of requirements for using specific type of flooring when Elpan/Wanpan  skirting board radiant heating system is installed.

For more information go to: www.wanpan-usa.com.

 

Tags: , , , , , , , , , , , , , , , , , , , , , , , ,

No Cracking Noise while Using the Elpan/Wanpan Ultimate Heating System

There is no cracking noise while using the Elpan/Wanpan ultimate heating system. You will find an explanation below – what is the main reason, that some customers experiencing cracking noise after they had installed skirting board heating system.Click to enlarge

Cracking noise may appear if the blind panels of the skirting board heating system are cut not as per mounting instructions, and there is not enough room left for metal expansion while heated. If construction/installation companies are not doing the heating trial for 1/2 hours before they cut blind panels, they may have blind panels being cut too long and no distance left for metal expansion. Then the cracking sound could appear.

Blind panels have to be measured and cut not earlier than after 1/2 hour of trial heating. Even after that, leaving 2-3 mm of the distance between blind panel and heating panel is strongly suggested. It will allow metal to expand even more –  silently, without making any noise.

There is no cracking noise while using Elpan/Wanpan ultimate heating system if the installation instructions of the skirting board heating system were followed completely.

For more information go to: www.wanpan-usa.com.

 
Leave a comment

Posted by on June 20, 2013 in Product and Installation

 

Tags: , , , , , , , , , , , , , , , , , , , , ,

Skirting Board Heating System Installed in Tunnels and Corridors

Skirting board heating system, installed in tunnels and corridors, appears to be the most suitable heating system for many reasons. Obviously,  Elpan/Wanpan skirting board heating system looks neat and Click to enlargesleek. Heating panels of skirting board heating system do not take additional space and softly flows into interior of design.

When tunnel or corridor is designed between two buildings, above street level, and has modern glass design, sun’s energy may be utilized efficiently and only few heating panels of baseboard heating system may be needed to be installed. At the same time, heating panels, incorporated into design of regular baseboards will not allow humidity or fogy condition to form onto huge windows.

Sometimes, two buildings with same or similar function need to be connected by tunnel, constructed under the ground ( two hospitals, with purpose to transport patients from one facility to another). Elpan/Wanpan heating system is practically the only one heating system, which keeps up with all the specifics of the construction.

Skirting board heating system, installed in tunnels and corridors, opens more options for energy efficient and compact Elpan/Wanpan heating system to be used for such unique application.

For more information go to: www.wanpan-usa.com.

 