No Cracking Noise while Using the Elpan/Wanpan Ultimate Heating System

There is no cracking noise while using the Elpan/Wanpan ultimate heating system. You will find an explanation below – what is the main reason, that some customers experiencing cracking noise after they had installed skirting board heating system.Click to enlarge

Cracking noise may appear if the blind panels of the skirting board heating system are cut not as per mounting instructions, and there is not enough room left for metal expansion while heated. If construction/installation companies are not doing the heating trial for 1/2 hours before they cut blind panels, they may have blind panels being cut too long and no distance left for metal expansion. Then the cracking sound could appear.

Blind panels have to be measured and cut not earlier than after 1/2 hour of trial heating. Even after that, leaving 2-3 mm of the distance between blind panel and heating panel is strongly suggested. It will allow metal to expand even more –  silently, without making any noise.

There is no cracking noise while using Elpan/Wanpan ultimate heating system if the installation instructions of the skirting board heating system were followed completely.

For more information go to: www.wanpan-usa.com.

 
Leave a comment

Posted by on June 20, 2013 in Product and Installation

 

Tags: , , , , , , , , , , , , , , , , , , , , ,

Elpan/Wanpan Heating for Hospital, Clinic or Medical Center

If specific indoor requirements  such as even temperature, lowest level of dust and conditionaly humid air are preserved in a hospital (intense care area, emergency or surgery room, etc.), patients of the hospital or medical center are exposed to the most healthy and hygienic environment. Also, it is equally important for doctors, surgeons and other medical personel, who perform complicated and precise medical procedures, to work in highly comfortable thermal (even temperature, floor is not heated) and hygienic (level of dust, conditionaly humid air) conditions.

Elpan/Wanpan skirting board radiant heating system radiats heat directly into room and reacts to the change of temperature of 0.5 degree of C (people, sunshine, medical equipment, etc.) and momentarily turns off/on heating. The lowest heat convection is a result of thermal encirclement. It helps to keep the lowest level of dust in all areas of the clinic or hospital where Elpan/Wanpan heating systems are installed.

Medical facilities are filled with high quality and sensitive technology to monitor sensitive data and often – to keep patients alive. No additional heat at floor level (infloor heating), uniform temperature, fast reaction to the change of temperature and lowest level of dust in the room helps to run medical equipment smothly.

Exceptional conditions of highest level of comfort and hygiene are achieved, when Elpan/Wanpan baseboard radiant heating system is used in hospital, clinic or other medical facilitiy. 

For more information go to: www.wanpan-usa.com.

 
Leave a comment

Posted by on October 10, 2012 in Application

 

Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Wanpan Hydronic Heating System – No Water Leaking Issues

Going through visual inspection or more detailed examination of ANY KIND of skirting board heating system, physical characteristics of heating panels, connections and other parts of the heating system have to be taken into consideration very seriously.

Metals and other materials have tendency to extand to a certain (individual) degree – when heated. Connecting two parts which have different  physical characteristics could cause water leaking problems, because of the qualities mentioned above.  

The construction of Wanpan hydronic heating system is based on scientific facts and numerous tests. PLEX pipes and Compression Connections along with aluminum surface of heating panels and copper made pipes make Wanpan hydronic skirting board heating system completed and highly reliable. 

When heating panels are mounted on to the wall, it is very important to run the trial test and check out all connections for water leak. Compression Connections of Wanpan hydronic baseboard heating system can hold up to 235 PSI ( 16 ATM ) preassure. Energy efficient Wanpan heating system is the reliable hydronic skirting board heating system.

Scientifically based choice of materials, carefully tested construction and high quality installation job is the key for uninterrupted performance of Wanpan hydronic baseboard heating system.

For more information go to: www.wanpan-usa.com.

 

Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Carpet Flooring and Elpan/Wanpan Ultimate Radiant Heating System

It is necessary to install the ultimate heating system, when going green and energy efficient, especially, if chosing carpet flooring. Recently, manufacturers are making thin carpet with a low pile and suggesting it to be used with any heating system, even infloor/underfloor heating systems. However, if heated floor of entire room are covered and heat has to pass through any additional layer (such as carpet), heating efficiency is affected significantly.

Conductivity of carpet is extremly low. Even if the surface of the floor (under the carpet) is heated to the max it will be very difficult to heat the room. In this case, Radiant Heating becomes Conductive Heating, which is one of the most unefficient ways to heat premises.

Energy efficient Elpan/Wanpan skirting board radiant heating system is absolutely suitable, when it comes to carpeted floor. The modular heating panels of Elpan/Wanpan ultimate radiant heating system are installed 0.5 inch from the floor level, so carpet may by layed just under the skirting board so ventilation holes stay uncovered.

For more information go to: www.wanpan-usa.com.

 