RSS

Tag Archives: Elpan heating

Perforated Surface of Heating Panels Designed to Increase Energy Efficiency

Perforated surface of heating panels is an additional detail added to increase energy efficiency of Elpan/Wanpan skirting board heating system. Warm air flows into the room faster and shorter period of time is needed for thermostats to react.
click to enlarge

When designing and manufacturing  Elpan/Wanpan  baseboard heating system, engineers and scientists were working on idea to create the high quality, low inertia and most efficient skirting board heating system.

Two rows of well designed neat perforation at the top and at the bottom area of heating panels is important final detail, which determines whole purpose of minimizing energy consumption in all possible ways and keeping the design of the heating system as much appealing as possible.   

Elpan electric and Wanpan hydronic skirting board heating systems are recognized as highly energy efficient heating systems as well as low inertia ones. Perforated surface of heating panels is just an additional component, which is added to improve a performance of heating system and to keep a design of the heating system unique and impeccable.

For more information go to: www.wanpan-usa.com.

 
Leave a comment

Posted by on April 22, 2014 in Design, Efficiency

 

Tags: , , , , , , , , , , , , , , , , , ,

Skirting Board Heating System Mounted on Uneven Wall Structure

Elpan/Wanpan skirting board heating system could be mounted on uneven wall struClick to enlargecture.

It is completely understandable, that to get the most impecable look, while having basebboard heating panels, the surface of the walls as well as a surface of the floor should be evenHowever, Elpan/Wanpan heating panels could be mounted on walls with uneven structure.

In many cases, Elpan/Wanpan  skirting board heating system is mounted on different structure walls, like wood or stone finished ones.  Heating panels of baseboard heating system, mounted on uneven structure walls, helps to keep sophisticated and modern indoor design, as well as maintain healthy environment while saving heating energy. The cost of regular baseboards is eliminated and it reduces cost of heating system in general.

If Elpan/Wanpan skirting board heating system is going to be mounted on uneven wall structure, high quality installation skills and precise job performance are required,

For more information go to: www.wanpan-usa.com.

 
Leave a comment

Posted by on March 30, 2014 in Design, Product and Installation

 

Tags: , , , , , , , , , , , , , , , , ,

Baseboard Heating Panels Help to Avoid Snow and Ice Accumulation on Roof Windows

Click to enlargeElectric Elpan baseboard heating panels, installed below roof windows, help to avoid snow and ice accumulation on roof windows. This is one of very specific skirting board heating system’s applications.

Often, big and high ceiling buildings have big number of roof windows. The roof windows are not only neat and updated contemporary design detail, but also a possibility to add more light and accumulate additional sun heat into premises. Modern architecture comes along with a challenge for building owners and property users –  to keep roof windows clear from snow and ice.

During cold winter days snowy and icy weather conditions may appear and roof windows are covered with snow and ice. Slim and neat Elpan modular heating panels are perfectly designed to be installed under roof windows. Click to enlargeLine of electric heating panels installed under roof windows keeps them free of snow and ice all the time. It is very beneficial not only for big constructions and office buildings, but as well as for private homes and cottages.

By istalling electric Elpan baseboard heating panels below the roof windows, accumulation of snow and ice is effortlessly avoided and sun light flows into the building without any interruption.

For more information go to: www.wanpan-usa.com.

 

Tags: , , , , , , , , , , , , , , , , , , , , ,

The Ultimate Heating System for Commercial Areas

There may be serious challenges to chose an ultimate heating system for commercial areas. Often walls need to be covered with shelves or wall displays which are full of prodClick to enlargeucts.

Energy efficient Elpan skirting board radiant heating system could be easily installed on the outside surface of shelves or displays. At this point, electric Elpan baseboard heating system is not only the heating system, but also –  an additional detail of design. Elpan modular heating panels are especially neat and slim to flow into indoor design inconspicuous.

Having infloor or underfloor radiant heating systems installed in commercial areas may cause some issues concerning higher temperatures at the lower level. Commercial products on the bottom shelves will be exposed to much higher temperature, which may not be recommended for specific merchandise. If infloor/underfloor heating areas would be adjusted acording shelves’ or bigger wall displays’ locations, it might be an inconvenience if store needs to be remodeled or updated in the future.

Energy saving Elpan ultimate heating system helps to keep the lowest level of dust, which also eliminates some additional cleanning work.The Thermal Encirclement effect, lowest possible air convection and possibility to be installed on the outside surface makes electric Elpan skirting board heating system to be recognized as the ultimate heating for commercial areas.

For more information go to: www.wanpan-usa.com.

 

Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Installing Elpan Skirting Board Radiant Heating System in Huge Space


Installing Elpan skirting board radiant heating system in church, which is huge space not only by big square footage, but also – by having very high ceilings – is the best way to save heating energy.

There is not a purpose such as –  to heat all church from floor to ceiling, but it is a desirable goal to keep people warm during activity hours. Heating systems which have high inertia (infloor heating) or low efficiency (traditional radiators or baseboard heaters) are to costly to be operated in these kind of buildings.

When Elpan electric modular heating panels are mounted under each seat, from both sides of the bench,  radiant heat is used right there, where it is needed the most. In addition to that,  Elpan radiant heating system could be installed on surrounding walls around the perimeter of the church.

It is necessary to install the ultimate heating system to keep all members of congregation feeling comfortable  when they are participating in church events. At this point – installing Elpan skirting board radiant heating system in church –  is one of the best ways to heat huge space and save heating energy. 

For more information go to: www.wanpan-usa.com.

 
Leave a comment

Posted by on June 30, 2013 in Application

 

Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,